| Specs - Volcanic Marine Industry Heater |
|
|
| Model - |
50 |
75 |
100 |
200 |
300 |
400 |
600 |
800 |
1000 |
1200 |
1500 |
1800 |
2000 |
Output Capacity
(Million BTU/Hr) |
0.50 |
0.75 |
1.0 |
2.0 |
3.0 |
4.0 |
6.0 |
8.0 |
10.0 |
12.0 |
15.0 |
18.0 |
20.0 |
Heat Transfer Surface
(sq. ft.) * |
55 |
85 |
111 |
220 |
335 |
445 |
670 |
890 |
1110 |
1330 |
1660 |
2000 |
2220 |
Thermal Liquid Fow
(GPM) ** |
50 |
60 |
75 |
150 |
225 |
300 |
425 |
600 |
725 |
900 |
1100 |
1350 |
1500 |
Coil Pressure Drop
(PSI) |
8 |
17 |
8 |
18 |
18 |
17 |
23 |
16 |
15 |
25 |
11 |
20 |
10 |
Circulating Pump
(HP) *** |
5.0 |
7.5 |
7.5 |
10.5 |
15.0 |
20.0 |
25.0 |
30.0 |
40.0 |
50.0 |
60.0 |
75.0 |
100.0 |
Burner Combustion Air
(cfm) |
114 |
170 |
228 |
456 |
684 |
912 |
1368 |
1824 |
2280 |
2740 |
3420 |
4100 |
4560 |
Blower Motor
(HP) |
1/3 |
0.5 |
0.5 |
1.0 |
2.0 |
3.0 |
5.0 |
7.5 |
15.0 |
20.0 |
25.0 |
30.0 |
40.0 |
|
* Provides a heat flux of 9,000 BTU/Hr. sq. ft.
** Based on an oil temperature increase of approximately 55°F through the heater.
*** Based on centrifugal pump @ 150 ft. TDH
|
|
|